Condition: | New |
---|---|
Customized: | Customized |
Certification: | CE |
Material: | PVC |
Type: | Medical Models |
Grade: | Top Quality |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
CPR280
Product Introduction:
The product functions are completely improved.It highlights the examination and judgment before CPR operation which much more in line with the real clinical CPR operation requirement,improving survival rate.
Features:
1. Simulate standard open airway.
2. External breast compression: display device and alarm device.
a. Indicator light display of correct and wrong compression; alarm of wrong compression;
b. Intensity display of correct (at least 5cm) and wrong (less than 5cm) compression; alarm of wrong compression. Digital strip indicator light (yellow, green, red) shows compression depth.
3. Artificial respiration (Inhalation): display device and alarm device.
a. Display of inhalation (≤500ml-600ml≤), strip indicator light shows inhalation volume; alarm of wrong operation.
b. Inhalation too quickly or too much result in air entering into stomach; indicator light display and alarm prompting.
4. Ratio of compression and artificial respiration: 30:2 (one or two person).
5.Operating cycle: 2times correct respiration, one cycle includes five times of 30:2 (one or two person).
6.Operation frequency: at least 100 times per minute 7.0peration methods: exercise operation.
2. Examination of pupil response: mydriasis and myosis.
3. Examination of carotid response: pinch the pressure ball by hand and simulate carotid pulse 10-Working conditions: Input power is 110-240V.
CPR260
Implement standard: American Heart Association(AHA ) 2015 Guideline for Cardiopulmonary Resuscitation(CPR) Emergency Cardiovascular Care(ECC).
Features:
1. Clear anatomic characteristic,realistic touch feeling and lifelike skin color,vivid appearance.
2. Simulate vital signs:
(1). Pupil state:contrast observation of pupils,one is dilated,the other one is contracted.
(2). Carotid artery response:squeeze the rubber ball to simulate carotid artery pulse.
3. Open airway.the airway indicator will turn green.
4. Can perform artificial respiration and extracardial compression.
CPR Monitor functions:
1. Available CPR training.
2. Electronic monitoring of compression site.
3. lndicators show inflation volume,correct inflation volume:500/600ml-1000ml.
(1). Insufficient inflation volume,yellow indicator.
(2). Proper inflation volume,green indicator.
(3). Excessive inflation volume,red indicator.
4. Indicators show compression depth:correct compression depth:4-5cm.
(1). Insufficient compression depth,yellow indicator.
(2). Proper compression depth,green indicator.
(3). Excessive compression depth,red indicator.
(4). Operation frequency:1 OOtimes/min,withl,tickl,sound.
(5). Operation cycle:2 valid inflation after 30 valid compression,5 cycles.
5. Power:220V,6V output powder via manostat;or use 4pcs 1 battery.
Material features:
The model is molded under high temperature by means of stainless mould.with face skin.neck skin.chest skin and hair made of imported material.lt features durability.non-deformation and easy assembly and disassembly.
CPR15230
Features:
1. Simulate standard open airway.
2. External breast compression: display device and alarm device.
1) Indicator light display of correct and wrong compression; alarm of wrong compression.
2) Intensity display of correct (at least 5cm) and wrong (less than 5cm) compression; alarm of wrong compression. Digital strip indicator light (yellow, green, red) shows compression depth.
3. Artificial respiration (Inhalation): display device and alarm device.
1) Display of inhalation (≤500ml-600ml≤), strip indicator light shows inhalation volume; alarm of wrong operation.
2) Inhalation too quickly or too much result in air entering into stomach; indicator light display and alarm prompting.
4. Ratio of compression and artificial respiration: 30:2 (one or two person).
5. Operating cycle: 2times correct respiration, one cycle includes five times of 30:2 (one or two person).
6. Operation frequency: at least 100 times per minute.
7. Operation methods: exercise operation.
8. Examination of pupil response: mydriasis and myosis.
9. Examination of carotid response: pinch the pressure ball by hand and simulate carotid pulse.
10. Working conditions: Input power is 110-240V.
Zhangjiagang Deren scientific equipment CO., LTD. is a combination of research and development, experiment, production, sales for the integration of modern scientific teaching medical infrastructure research and development manufacturing enterprises, adhering to the from teaching, return to education survival mission, after the medical professional learning-doctors-teachers-foreign research and development technical personnel-foreign senior management-self-employed career change, Deren was established in 2011. After two years of research and development between 2012 & 2013 , we accumulated steadily and launched Deren brand series of teaching supporting facilities for the world from year 2014,. Adhere to the professional, dedicated, lean, practical enterprise philosophy, from their own professional continuous improvement to product quality excellence, from the user's practical recognition to the continuous innovation and development new products, Deren development has always been adhering to development of this basic concept pursuit. Following the corporate culture thought of social virtue, benevolence, guiding and influencing the Deren staff to persevere and constantly pursue the perfect combination of professional and fighting spirit of science and art. Deren is located in Zhangjiagang, near Yangtze River Delta economic zone in eastern China, by the spirit of heaven and earth. Grasp the east wind of reform and opening up, borrow the treasure of south of Yangtze River omen, entrepreneurship, development, innovation, promotion- -this is the benevolence, social commitment, benevolen.